Dublin · House extension · Worked example
Sizing rainwater planters for a 40 m² roof
How do roof area and rainfall become a planter size? Here is the calculation for a small Dublin extension, with its roof split equally between two downpipes.
By Rainplanter · 4 November 2026. This is an illustrative project using a recorded Met Éireann rainfall lookup. It is not a completed installation, site survey or approved planning design.
The example result
Two planters, 2100 × 600 × 600 mm each
- Roof per planter
- 20 m²
- Storage needed per planter
- 365 litres
- Storage provided per planter
- 365.4 litres
A suitable restricted outlet is assumed for each planter. These are the calculator’s storage dimensions; the final outside footprint depends on the construction details.
1. Set the roof and drainage assumptions
The connected roof area is 40 m². Two downpipes each serve 20 m² and each feeds one planter. The selected “Sewer / Soakaway” option assumes a suitable onward connection, with the calculator crediting a restricted discharge of 0.2 litres/second per planter.
The calculation uses 100-year rainfall, a 20% climate allowance and a roof runoff coefficient of 0.95. These are the tool’s design assumptions. The connection, discharge limit and project requirements still need agreement for the actual site.
If your downpipes drain unequal roof areas, do not copy the equal split. Size for the area actually connected to each planter. An ordinary open pipe also does not establish the assumed restricted flow.
2. Find the storm that needs the most storage
For the recorded Dublin point, the 15-minute, 100-year rainfall depth is 23.9 mm. Adding 20% gives 28.68 mm. Rainplanter checks the returned durations from 15 minutes to 24 hours; the largest inflow-minus-outflow result controls.
Inflow per planter: 20 m² × 23.9 mm × 1.20 × 0.95 = 544.92 litres
Credited outflow: 0.2 L/s × 15 minutes × 60 = 180.00 litres
Required storage: 544.92 − 180.00 = 364.92 litres, displayed as 365 litres
One millimetre of rain on one square metre equals one litre. Longer storms bring more rain, but also allow more time for the restricted outlet to drain. That is why the wettest total rainfall is not necessarily the controlling storage event.
See every checked storm duration
| Minutes | Rain, mm | Inflow, L | Outflow, L | Storage, L |
|---|---|---|---|---|
| 15 · critical | 23.9 | 544.92 | 180.00 | 364.92 |
| 30 | 29.6 | 674.88 | 360.00 | 314.88 |
| 60 | 36.6 | 834.48 | 720.00 | 114.48 |
| 120 | 45.2 | 1030.56 | 1440.00 | 0.00 |
| 180 | 51.2 | 1167.36 | 2160.00 | 0.00 |
| 240 | 55.9 | 1274.52 | 2880.00 | 0.00 |
| 360 | 63.3 | 1443.24 | 4320.00 | 0.00 |
| 540 | 71.7 | 1634.76 | 6480.00 | 0.00 |
| 720 | 78.3 | 1785.24 | 8640.00 | 0.00 |
| 1080 | 88.6 | 2020.08 | 12960.00 | 0.00 |
| 1440 | 96.8 | 2207.04 | 17280.00 | 0.00 |
3. Turn storage into planter dimensions
The designer starts this example at 2.1 m long × 0.6 m wide × 0.6 m deep. Its footprint is 1.26 m². Only part of the planter volume stores water: the tool allows 150 mm of surface ponding, 300 mm of soil at 30% storage and 150 mm of gravel at one-third storage.
Equivalent water depth: 0.15 + (0.30 × 0.30) + (0.15 × ⅓) = 0.29 m
Usable storage: 2.10 × 0.60 × 0.29 × 1,000 = 365.4 litres per planter
The two selected planters provide 730.8 litres in total, against 730 litres of displayed required storage. This example has no calculated storage shortfall. Different roof areas, locations or outlet arrangements can leave a shortfall that must be provided elsewhere.
4. Apply the example to your own extension
Use your project location, connected roof area, downpipe arrangement and outlet choice in the free rainwater planter calculator. Check the dimensions and storage shown on page two. The example uses a fixed rainfall point, so entering a nearby place name can give slightly different rainfall and results.
Before using a proposal for planning or construction, check the permitted outlet, excess-water route, levels, maintenance access and final construction with your designer. Do not use this outlet-connected result for the “Nowhere / not sure” option, which uses a different design check.
The optional €20 drawing pack records your own selected design for review. This worked example is free to read and does not require a purchase. For underground infiltration, see the Soakaway worked example for a 40 m² roof.
Rainfall source and reproducibility
Rainfall was retrieved on 4 November 2026 from Met Éireann’s rainfall return period calculator, which identifies its basis as the 2023 DDF model update. The reference point is Irish Grid E 315900.56, N 234671.36 in Dublin.
View the recorded rainfall inputs and source query. The results above use the same calculation and storage functions as Rainplanter; no live rainfall lookup is needed to read this page. See the sizing and planning guide for the wider assumptions.